Layout Diagrams; Screw-In Heater Mounting Set - Dimplex CTHK 630 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.2

5.2 Layout diagrams

E-4

5.3 Screw-in heater mounting set

In addition to national legal regulations, the user must also
comply with the connection requirements of the local power and
water supply companies.
1)
Completely (end stop) screw the Calogen heating elements
into the thread of the cylinder connecting sleeve, test for
tightness and re-tighten if necessary. Use hemp or Teflon
tape for sealing if necessary.
2)
Remove the dust cap.
3)
Set up electrical connection according to circuit diagram
(see 5.6). Ensure that the electric cable has the appropriate
strain relief.
ATTENTION!
Do not forget the protective conductor connection!
4)
Replace dust cap and screw into place, insert the supplied
control knob.
ATTENTION!
The cylinder must be filled with water prior to start-up.
5)
After filling the cylinder, check the screw connection of the
heating element for leakage, if necessary re-tighten the
screw-in heater.