FAULT MESSAGES FROM THE DIGITAL CONTROLS (E2)

Error
No.
Name
E2
03
Key pad permanently on
LIN Bus opened
E2
05
Wiring interruption
E2
10
Faulty ID
E2
11
Self diagnosis error
Invalid configuration data
E2
13
Supply voltage
E2
14
Compatibility of LIN version LIN version is not compatible
E2
20
Unknown error
E2
FF
Caution: During cleaning, do not wash the external parts of the appliance with direct or high pressure water jets.
Every evening, after use, clean the appliance thoroughly. Daily cleaning after switching off the appliance ensures the
perfect functioning and long life of the appliance.
Before starting to clean the appliance, disconnect the power supply. The steel parts must be washed with hot water and
neutral detergent, then rinsed thoroughly in order to eliminate all traces of detergent. They should then be dried with a
dry cloth. Do not use abrasive or corrosive detergents.

Cleaning the glass

The glass should be washed with vinegar or lemon-based degreasers, suitable for cleaning ceramics and glass.
During this operation, it is best for the glass not to be completely cold, so that spilt food, burnt fat and other substances
can be softened with a damp cloth and removed whilst still warm with a scraper, so as to prevent the glass surface from
deteriorating.
Do not use abrasive or corrosive detergents.
PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR
Clean and dry the appliance carefully according to the instructions. Disconnect the power supply.

PROCEDURE TO FOLLOW IN THE EVENT OF A BREAKDOWN

In the event of breakdown, turn off the appliance, disconnect the power supply by using the device situated above the
appliance and notify the after sales service.

MAINTENANCE (ONLY FOR QUALIFIED PERSONNEL)

Any kind of maintenance must only be done by qualified personnel. Before carrying out maintenance, remove the plug
or switch off the switch above the appliance.
GB
Cause
Water or cookware on the
control glass
Key button defect
No detection of communication
Faulty connection between
key pad and generator
Digital control has a faulty ID
Self diagnosis of Software
located error
The device found no valid
configuration data
Problem with supply voltage of
the key pad
An error occurred, its cause is
unknown

CLEANING AND MAINTENANCE

SOME TIME
51
IE
Corrective action
Clean control area
Replace digital control unit
Check LIN Bus
Replace connecting cable
Switch the generator off, adjust
the DIP-switches correctly
Switch the power off and on,
if the error remains contact
customer support
Contact customer support.
Automatic reset
Contact customer support
Contact customer support.

Publicité