2.
Lift and turn the coil support plate so that the arrow with
nail size indicated on the coil support plate will point to the
corresponding graduation increment marked on the magazine.
2
► 1. Coil support plate 2. Graduation 3. Arrow
3.
Place the nail coil over the coil support plate.
Uncoil enough nails to reach the feed claw. Place the
first nail in the driver channel and the second nail in the
feed claw. Place other uncoiled nails on feeder body.
Close the magazine cap after checking to see that the
nail coil is set properly in the magazine.
► 1. Feed Claw
Connecting air hose
► 1. Air fitting 2. Air socket
Slip the air socket of the air hose onto the air fitting on
the nailer. Be sure that the air socket locks firmly into
position when installed onto the air fitting.
A hose coupling must be installed on or near the tool in
such a way that the pressure reservoir will discharge at
the time the air supply coupling is disconnected.
1
3
1
1
2
OPERATION
CAUTION:
Make sure all safety systems are in
working order before operation.

Selecting the operation mode

CAUTION:
Always make sure that the actua-
tion mode selector is properly set to the position
for the desired nailing mode before nailing.
1
► 1. Actuation mode selector
Single sequential actuation mode:
You can drive one nail by one sequential operation.
Select this mode when driving a nail carefully and
accurately.
To choose this mode, set the actuation mode selector to
the
position.
Contact actuation mode:
You can drive nails repetitively by placing the contact
element with the trigger held.
To choose this mode, set the actuation mode selector to
the
position.
Single sequential actuation
CAUTION:
Do not place the contact element
against the workpiece with excessive force. Also,
pull the trigger fully and hold it on for 1-2 seconds
after nailing.
Even in the "Single sequential actuation" mode, half-
pulled trigger causes an unexpected nailing, when the
contact element re-contacts the workpiece.
Place the contact element against the workpiece and
pull the trigger fully.
After nailing, release the contact element, and then
release the trigger.