4 Setting and operation
4.1 Display on control panel:
Running capacity / Flow rate
Timer period
Backwash / unlock
Up: to change the value (capacity / flow / time)
Down: to change the value (capacity / flow / time)
Timer setting
On / off
Switch for Auto-Inverter Mode/Manual-Inverter Mode
Auto-Inverter Mode: The pump's running capacity be automatically adjusted between 30%-100%
according to the setting flow rate to ensure a constant flow.
Manual-Inverter Mode:The pump's running capacity be set manually between 30%-100%
The default mode is Auto-Inverter mode.
4.2 Startup
When the power is switched on, the screen will be fully light for 5 seconds, the device code will be displayed,
and then it will enter the normal working state. When the screen is locked, only the button
and hold
for more than 3 seconds, other buttons will all light up. The screen will automaticlly lock up when
there is no operation for more than 1 minute and the brightness of the screen is reduced by 1/3 of the normal
display. Short press
to wake up the screen and observe the relevant operating parameters.
8
Power consumption
Timer
WIFI indicator
Unit of flow
owill light up; Press