7.3 Undervoltage protection
When the device detects that the input voltage is less than 200V, the device will limit the current running speed.
–
When input voltage is less than or equal to 180V, the running capacity is limited to 70%;
–
When the input voltage range is 180 to 190V, the running capacity is limited to 75%;
–
When the input voltage range is from 190V to 200V, the running capacity is limited to 85%.
Problem
Pump does not start
Pump won't prime
Low water flow
Pump being noisy
26
Corrective solution
–
Power Supply fault, disconnected or defective wiring.
–
Fuses blown or thermal overload open.
–
Check the rotation of the motor shaft for free movement and lack of
obstruction.
–
Because of long time lying idle. Unplug the power supply and manually
rotate motor rear shaft a few times with a screwdriver.
–
Empty pump/strainer housing. Make sure the pump/strainer housing is filled
with water and the O ring of cover is clean.
–
Loose connections on the suction side.
–
Strainer basket or skimmer basket loaded with debris.
–
Suction side clogged.
–
Distance between pump inlet and liquid level is higher than 2m, height of
pump installation should be lowered.
–
Pump is not primed.
–
Air entering suction piping.
–
Basket full of debris.
–
Inadequate water level in pool.
–
Air leak in suction piping, cavitation caused by restricted or undersized
suction line or leak at any joint, low water level in pool, and unrestricted
discharge return lines.
–
Vibration caused by improper installation, etc.
–
Damaged motor bearing or impeller (need to contact the supplier for repair).