0
G20 20 mbar / G20Y20 20 mbar
3.5 Adjustment of minimum level
WARNING!
Information for authorised installer only.
Switch off the hob before the adjustment.
To adjust the minimum level of the burners:
1. Deactivate the hob.
2. Press and hold
3. Within 7 seconds, press and hold the
space below the three illuminated LEDs
next to the
symbol for 3 seconds.
4. Press
symbol of the middle burner 3
times.
The display shows G2 mode.
5. To enter the mode press
middle burner.
6. Wait 5 seconds after selecting the mode.
The burner ignite at minimum level and the
control bar shows
7. To increase or decrease the value and
adjust the minimum level press
symbols of the middle burner.
8. Wait 5 seconds to send the selected
value to power board.
9. Check if the minimum level is correct and
press
symbol to confirm the minimum
level.
If the minimum level is incorrect, repeat
the steps 6 and 7.
10. Press
symbol of the middle burner to
select the next burner and repeat the
steps 5-8.
The procedure starts from the middle burner
and goes through the left burner, the right
front burner to the right rear burner.
Liquid gas 29 mbar
for 3 seconds.
symbol of the
.
or
Gas selection
1
To exit the mode press
WARNING!
Make sure the flame does not go out
when you move quickly from the
maximum to the minimum heat setting
position.
WARNING!
Do not set the G3 and G4 modes. It is for
Authorised Service Centre only.
3.6 Electrical connection
• Make sure that the rated voltage and type
of power on the rating plate agree with the
voltage and the power of the local power
supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a correct
plug which can hold the load that the
rating plate rates. Make sure that you
install the plug in a correct socket.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to the
mains plug after the installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• There is a risk of fire when the appliance
is in connection with an extension cable,
an adapter or a multiple connection. Make
sure that the ground connection agrees
with the standards and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90°C.
To prevent contact between the cable and the
appliance below the hob use the clamps
which are on the side of the cabinet.
2
Safety risk, do not use 2 gas selec‐
tion. Use only 0 or 1 gas selections
depend on gas supply.
.
ENGLISH
9