Taking Out Of Service And Disposal; Technical Specifications - ASO Safety Solutions ELMON inductive 70-755 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Inducti ve signal transmission system

12. Taking out of service and disposal

The products manufactured by ASO are intended solely for commercial use (B2B). At the end of use, the
products are to be disposed of according to all local, regional and nati onal regulati ons. Products can also be
returned to ASO, which will then dispose of them properly.
13. Technical specifi cati ons
Supply voltage
extra low voltage
Power consumpti on
Current consumpti on
Terminal resistance of the safety contact edges
nominal value
upper switching point
lower switching point
Switching ti mes
Switching off delay (response ti me)
Weight
Temperature range
Protecti on class
Recommended protecti on for
installati on
ELMON inducti ve 70-755 connector
Molex KK3,96 type 3215A
20
U
24 V DC +/-10 %
E
P
< 1 W
E
I
35 mA
E
R
= 8,2 kΩ
nom
R
> 20,0 kΩ
AO
R
< 2,5 kΩ
AU
t
< 30ms
a
ca. 15 g
-25 °C to +55 °C
IP00
IP54
EC type examinati on no.:
44 205 12 413159-001
Test report no.:
12 205 413159-001

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Indus 70-755

Table des Matières