System Components Fitted To The Gate; Device Overview; Signal Indicators; Connection Terminals - ASO Safety Solutions ELMON inductive 70-755 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Inducti ve signal transmission system
5. System components fi tt ed to the gate
1
1 2
2
Example of use
The actual arrangement of the individual compo-
nents depends on the design of the gate in questi on
and the conditi ons at the installati on site.

6. Device overview

6.1 Signal indicators

LED POWER green
LED FAULT OPEN red
LED FAULT CLOSE red
V1.0: If no error is present, then LED Power shows the functi on control (briefl y off ).
V4.0 and later: If no error is present, then LED Power shows the operati ng state (on).
During the output of an error message, the number of output pulses indicates the error:
Pulse
1
2
5
6.2 Connecti on terminals
Pin 1, 2
Stati onary coil core
Pin 3
Supply voltage +24 V DC
Pin 4
GND
Pin 5, 6
Output Stop closing movement
Pin 7, 8
Output Stop opening movement
Pin 9
Test input
Pin 10
No assignment
16
2
1 Control device ELMON inducti ve 70-755
2 Stati onary coil core
3 Travelling coil core
4 Steel cable acti ng as transmission medium
V1.0: Functi onal test (off briefl y)
V4.0 and later: operati ng state (on)
Error message (pulse output)
Fault, opening movement - travelling safety contact edge(s)
Fault, closing movement - travelling safety contact edge(s)
Error message
Voltage supply outside of the valid value range
inducti ve signal transmission system error
Data transmission with microcontroller faulty
1
2
3
4
5
6
7
8
9
10
4
3
LED
Power
LED
Fault Opening
LED
Fault Closing

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Indus 70-755

Table des Matières