Hardwire Installation; Heater Hardware Disconnect - Dimplex Revillusion Rev24-Nb Guide D'installation Et D'utilisation

Table des Matières
Les langues disponibles

Les langues disponibles

Installation
120 V Hardwire Installation
Use 2-conductor wires with ground (3 wires total) from
the power supply (breaker panel) to the junction box on
the built-in electric firebox.
1. Connect the white wire from the unit to the neutral
wire from the power supply.
2. Connect black wire from the unit to the live wire from
the power supply.
3. Connect the green ground wire from the unit to the
ground from the power supply.
4. Insert all the wiring back into the firebox and secure
with a cable clamp (not included).
5. Make sure all connections are tight.

Heater Hardware Disconnect

The fireplace heater can be permanently disabled by
removing the electronic jumper on the main control
board.
!
NOTE: Heater hardware disconnect will permanently
disable the heater and fan. Follow these instructions
only when an installation without heat is required.
Temporary disabling of the heater can be achieved
through the hidden touch controls. See "Heat
Disable" in Operation section (page 16) for
instructions.
To disconnect the heater and fan permanently:
1. Locate and remove the panel on the top left of the
unit.
2. Pull out the heater hardware disconnect jumper
labeled "HT EN". (Figure 11)
3. Reinstall the previously removed panel.
Figure 10
120 V Hardwire Installation
White
Black
Green
Blanc
Noir
Vert
Figure 11
Neutral
Live
120 V
Power supply
Ground
Neutre
Conducteur
120 V
Alimentation
Terre
13