Installation
Electrical Installation
WARNING:
The installation of the electric fireplace must comply with the applicable Local and/or National Electrical Codes
and utility requirements. Employ qualified personnel where required by law.
Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the
risk of fire, electric shock, or injury to persons.
CAUTION: A dedicated, properly fused 15 Amp circuit is recommended, rated for the appropriate voltage
(120 V). A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular
basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of
the circuit breaker.
General Electrical
1. All wiring must be completed prior to installing the built-in electric firebox.
2. Allow 8" (20.3 cm) of service cable for connecting power supply wire to junction box on the unit when installing
and before finishing the wall. Allow up to 4 ft (122 cm) of service cable for connecting power supply wire to
junction box when installing after finishing wall.
3. Wire a dedicated, properly fused circuit with a 15 A rating for the appropriate voltage (120 V).
4. Secure the service cable through the electrical cover on the back of the unit and secure using a 1/2" approved
strain relief connector (not provided).
5. Remove the outer jacket and strip the individual conductors 1/2" (1.3 cm) from the end.
6. Follow the following instructions for your specific installation.
7. Wiring inspection can be done from the front of the unit: remove the access panel, to the right of the controls, to
access the service cable and wires from the unit.
8. The fireplace can be hardwired with a wall switch. The switch must be rated for a minimum of 15 A.
!
NOTE: For 120 V installation with wall switch, use a single pole, single throw (On/Off) wall switch.
Cord Length: 72" (183 cm)
WARNING: This heater is not intended for use with an extension cord. Plug the cord directly into an ap propriate
wall receptacle. must comply with the applicable Local and/or National Electrical Codes and utility requirements.
!
NOTE: The power cord installation must comply with the applicable Local and/or National Electrical Codes and
utility requirements.
12