Environment: Indoor
Relative Humidity: < 85% non-condensing
Operating Temperature: 32° to 140°F (0° to 40°C)
Storage Temperature: 14° to 122°F (-10°C to 50°C)
Operating Altitude: Up to 6562 ft. (2000 m)
Weight: 1.2 oz. (33 g)
Nominal Voltage: 110 - 125V AC at 50/60Hz in 3-wire outlet
Mains Supply Voltage Fluctuations: ±10%
Pollution Degree: 2
Nominal Power: 0.3W
Standards:
Conforms To UL Std 1436
Certified To CSA Std C22.2 #160
5030000
Drop Protection: 6.5' (2 m)
Safety Rating: CAT II 300V
CAT II: Measurement Category II is applicable to test and measuring circuits
connected directly to utilization points (socket outlets and similar points) of the
low-voltage MAINS installation.
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe
injury or death. Retain these instructions for future reference.
• Failure to follow instructions could result in death or serious injury.
• Before each use, verify tester operation by testing on a known live and correctly
wired receptacle.
• Do not use if the tester appears damaged in any way.
• The tester is intended for indoor use only.
• Other equipment or devices attached to the circuit being tested could interfere with
the tester, clear the circuit before testing.
• This tester only detects common wiring problems.
• Always consult a qualified electrician to resolve wiring problems.
FIG. 2
INDICATOR
Open Ground
Open Neutral
Open Hot
Hot/Ground Reversed
Hot/Neutral Reversed
Correct
Neutral (White)
GENERAL SPECIFICATIONS - RT210
WARNINGS
FAULT
Indicator
Illuminated
EXPLANATION
Ground contact is not connected
Neutral contact is not connected
Hot contact is not connected
Hot and ground connections are reversed
Hot and neutral connections are reversed
Receptacle is wired correctly
Hot (Black)
Ground (Green)
Indicator
Not Illuminated
7