All those elements needs to be linked together, the RF link procedure can be done in this order:
Element 1 to link
BT-M6Z02-RF
BT-M6Z02 RF
BT-M6Z02-RF
BT-M6Z02 RF
Press OK for 5 seconds, first channel
LED must blink.
Choose the channels with < and > and
select/deselect the zone with OK.
When a zone is selected it turns Red.
Note: To exit, press OK for 5 seconds.
BT-M6Z02-RF
BT-M6Z02 RF
Press < for 5 seconds, all channel leds
must blink Green. Product is waiting for
link.
Note: To exit, press < for 5 seconds.
BT-M6Z02-RF
BT-M6Z02 RF
Press < for 5 seconds, all channel leds
must blink Green. Product is waiting for
link.
Note: To exit, press < for 5 seconds.
BT-M6Z02-RF
BT-M6Z02 RF
Press < for 5 seconds, all channel leds
must blink Green. Product is waiting for
link.
Note: To exit, press < for 5 seconds.
Element 2 to link
BT-S4Z / BT-S6Z
BT-S6Z02 RF
BT-D(P)02-RF / BT-A02-RF
BT-D02 RF
BT-A02 RF
or
Thermostats :
Put product in RF Link mode
(refer to correspondant
instruction manual)
BT-WR02-RF
BT-WR02 RF
Put product in RF Link mode.
BT-WR02-RF + BT-D02-RF
BT-D02 RF
+
BT-WR02 RF
BT-WR02-RF must have
been first linked with the
thermostat.
Put BT-WR02-RF in RF Link
mode.
BT-HCM02-RF
BT-HCM 02 RF
Put product in RF Link mode.
7
Comments
No need to link them, just
assemble S4Z or S6Z with BT-
M6Z02-RF (both products OFF
powered) and you can select the
additional zones
If link is done, the leds of channels
selected on the BT-M6Z02 RF
must turn Green and the
thermostats must exit the RF link
mode.
In this configuration, BT-WR-
WR02-RF is used as on remote
pump device or boiler: if there is
a demand on the BT-M6Z02-RF,
the device will command the
output.
When link is done BT-M6Z02-RF
And BT-WR02-RF return to normal
mode
REMARK: instead of BT-WR02-
RF, you can also use BT-FR02-RF
and BT-PR02-RF
In this configuration, BT-WR-
WR02-RF is used as additional
zone.
When link is done BT-M6Z02-RF
And BT-WR02-RF return to normal
mode
REMARK 1: instead of BT-WR02-
RF, you can also use BT-FR02-RF
and BT-PR02-RF
REMARK 2: this confguration is
only possible in Heating
installation (no cooling)
When link is done BT-M6Z02-RF
And BT-HCM02-RF return to
normal mode at the same time.