1 USER GUIDE
The Connecting box BT-M6Z02-RF is especially designed to control your Under Floor Heating and Cooling
system.
It can handle Normally Closed or Normally Opened actuators.
Connecting box has by conception 6 outputs actuators and this number can be extended to 10 or 12 with an
extension.
BT-M6Z02-RF works with thermostats linked in RF; it can have up to 12 thermostats linked to it and handle 12
independent regulations in parallel.
It works with all thermostats of BT02 RF range.
Special features of BT-M6Z02-RFare:
-
pump or boiler output (wired or wireless with BT-WR02-RF)
-
Humidity management (via BT-D02-RF RH and BT-DP02-RF RH)
-
Heat and Cool signal input management (via BT-HCM02-RF)
-
Dehumidifer output (via BT-HCM02-RF)
-
Connection with BT-CT02-RF central unit

2 TECHNICAL CHARACTERISTICS

Operating Temperature
Regulation
characteristics
Supply Voltage
Outputs:
Pump or accessories
Actuators
Radio Frequency
CE Directives
Your product has been
designed in conformity
with the European
Directives.
Protection
Compatibility
BT-M6Z02-RF 230V
Proportional Integral regulation or Hysteresis regulation. Regulation is defined
by thermostat linked to channel (see thermostat leaflet)
230VAC +- 10% 50Hz
Relay => 5A / 250VAC (Free
contact)
Relay => 5A / 230 VAC ( L, N)
For easy installation we
recommend a maximum of 4
actuators by zones.
868, 3 MHz, <10mW.
Range of approximately 180 meters in open space.
Range of approximately 50 meters in residential environment.
With BT S4Z02 RF: 10 Zones => 1 Master 6 + 1 Slave 4 zones
With BT S6Z02 RF: 12 Zones => 1 Master 6 + 1 Slave 6 zones
0°C to 50°C
24Vac +- 10% 50Hz
Relay => 5A / 250Vac (free contact)
Triac => 3A / 24Vac
Total number of actuators is limited by
transformer (60VA) and fuse (2,5A)
and power of actuators.
R&TTE 1999/5/EC
LVD 2006/95/EC
EMC 2004/108/EC
RoHS 2011/65/EU
IP 30