Standard Mode; Starting The System - Girsberger ATC Manuel D'utilisation

Avalanche training center
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Standard Mode

In standard mode, the selected number of transmitters is activated at random, and the stopwatch is started.
Three consecutive probe hits, one second apart each, on the probing surface will cause an optical and
acoustic indication at the control unit. The activated transmitters keep transmitting even after a probe hit.
This corresponds to a realistic situation. Most transceivers provide facilities to mark found transmitters.
When all transmitters have been hit by a probe or when the maximum duration of the exercise has elapsed,
the end of the exercise is signaled acoustically.
After termination of the exercise, the search times for the individual transmitters can be read out on the
control unit.

4.1 Starting the System

W ak i n g u p . . .
T im e
: 0 0 m 35s
Se ar c h i n g - >
5
1 2 3 4 5
Search complete
1 2 3 4 5 6 7 8
V ict i m s : 0
T ime
: 10 m 00s
When the START / STOP key is pressed, the system will be started up
within 35 seconds.
After the startup, an automatic search for all available transmitters is
activated.
All transmitters that have been found will be indicated. Only those can
be used for exercises in the standard or expert mode.
The system is now ready.
33

Publicité

Table des Matières
loading

Table des Matières