Reporting codes
Table 5: 3G4010/LE4010/LE4010E reporting codes
Reporting codes
CID
Zone 1 Activation
E11A 991
Zone 1 Restoral
R11A 991
Zone 2 Activation
E12A 992
Zone 2 Restoral
R12A 992
Zone 3 Activation
E13A 993
Zone 3 Restoral
R13A 993
Zone 4 Activation
E3AA 994
Zone 4 Restoral
R3AA 994
PSTN Line Down
E351 000
PSTN Line Restoral
R351 000
Input Loss
E337 000
Input Restoral
R337 000
Low Battery Alert
E338 000
Low Battery Restoral
R338 000
Periodic Test
E603 XXX
Periodic Test with
E608 XXX
Trouble
Radio Activation
R552 000
Internal Buffer Full
E624 000
FTC Restoral
R354 000
Firmware Update
R901 000
Successful
Firmware Update Fail E902 000
Firmware Update
E901 000
Begin
System Tamper
E145 000
System Tamper
R145 000
Restore
* C24 Communications default value
SIA
FA 991
FH 991
PA 992
PH 992
BA 993
BH 993
YX 994
YZ 994
LT 000
LR 000
YP 000
YQ 000
YT 000
YR 000
RP XXX
RY XXX
RS 000
JL 000
YK 000
LS 000
LU 000
LB 000
ES 000
EJ 000
3G4010 V4.0 / LE4010 V5.1 / LE4010E V5.1 Installation manual
© 2025 Johnson Controls. All Rights Reserved.
Programmable
Comments
YES
Delayed 24 Hour Fire
*
YES
Delayed 24 Hour Fire
Restore *
YES
Panic Alarm *
YES
Panic Alarm Restore*
YES
Burglary *
YES
Burglary Restore *
YES
System Trouble *
YES
System Trouble
Restore *
FIXED
Telco 1 Fault
FIXED
Telco 1 Fault Restore
FIXED
Power Supply
Trouble
FIXED
Power Supply
Trouble Restore
FIXED
Transmitter Battery
Trouble
FIXED
Transmitter Battery
Restore
FIXED
Test Transmission
<Receiver Path>
FIXED
Test Transmission
<Receiver Path>
FIXED
Remote
Programming
Successful
FIXED
FIXED
Communications
Restored
FIXED
FIXED
FIXED
FIXED
Case Tamper
FIXED
Case Tamper Restore
Operating principles
17