Step 3 - Carrier Scanning Due To Insufficient Signal Strength; Step 4 - Acquire C24 Communications Programming; Step 5 - Receiver Initialization - Johnson Controls 3G4010 V4.0 Manuel D'installation

Table des Matières
Les langues disponibles

Les langues disponibles

In this state, the 3G4010/LE4010/LE4010E is unable to register to the cellular network because it is inactive. The
signal strength indicated is from any nearby cell tower (including cellular towers belonging to non-roaming
partners) and does not necessarily reflect the signal strength of the intended network. The 3G4010/LE4010/
LE4010E will remain in this state until the SIM is activated. Once the SIM is activated, the 3G4010/LE4010/LE4010E
will move to Step 2a.
Step 3 – Carrier scanning due to insufficient signal strength
The 3G4010/LE4010/LE4010E scans the surrounding network and connects to the carrier to provide a signal
strength of at least 7 CSQ. While this action is being performed, all four LEDs activate to show a scanning sequence
in progress. The LEDs cycle from top to bottom and then bottom to top until the 3G4010/LE4010/LE4010E
connectes to a carrier with a signal strength above 7 CSQ (minimum of bottom signal strength LED on solid).
Red
FLASHING ON
OFF
OFF
OFF
OFF
OFF
FLASH ON
Once this is completed, the 3G4010/LE4010/LE4010E proceeds to Step 4.

Step 4 - Acquire C24 communications programming

The red LED will be on solid and the blue LED will flash. The flashing of the blue LED indicates that the 3G4010/
LE4010/LE4010E has requested programming from C24 Communications and is waiting for a response.
Red
ON
Once remote programming is complete, the blue LED turns solid and the 3G4010/LE4010/LE4010E will move to
Step 5.
Step 5 – Receiver initialization
The red LED and the blue LED are both solid and the signal strength LEDs are off.
Red
ON
When the 3G4010/LE4010/LE4010E sends a request to communicate with the central station, the top signal
strength LED begins flashing.
Red
ON
When the central station responds to the 3G4010/LE4010/LE4010E, the top signal strength LED turns on solid.
Blue
OFF
FLASH ON
OFF
OFF
OFF
FLASH ON
OFF
Blue
FLASHING
Blue
ON
Blue
ON
© 2025 Johnson Controls. All Rights Reserved.
Yellow / Green (High)
OFF
OFF
FLASHING ON
OFF
FLASHING ON
OFF
OFF
Yellow / Green (High)
-
Yellow / Green (High)
OFF
Yellow / Green (High)
FLASHING
3G4010 V4.0 / LE4010 V5.1 / LE4010E V5.1 Installation manual
Installing the 3G4010 / LE4010 / LE4010E
Yellow / Green (Low)
OFF
OFF
OFF
FLASH ON
OFF
OFF
OFF
Yellow / Green (Low)
-
Yellow / Green (Low)
OFF
Yellow / Green (Low)
OFF
11

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Le4010 v5.1Le4010e v5.1Dsc 3g4010cfDsc le4010cfDsc le4010ecf

Table des Matières