MAX-SETHEATER
MIN-SETHEATER
MAX-SIGHEATER
MIN-SIGHEATER
TBH function
Other
heat
source
dT5_TBH_ OFF
t_TBH_DELAY
T4_TBH_ON
P_TBH
Solar function
Solar control
Deltatsol
Preheating for floor
T1S
t_ARSTH
Floor drying up
Special
function
t_Dryup
t_Highpeak
t_Drydown
t_Drypeak
Start time
Start date
Auto restart
Auto
cooling/heating mode
restart
Auto restart DHW
mode
Power
Power input
input
limitation
limitation
M1 M2
Smart grid
Input
definition
T1T2
Tbt
P_X port
PER_START
Cascade
setting
TIME_ADJUST
Maximum set temperature of additional
heating source
Minimum set temperature of additional
heating source
The voltage corresponding to the
maximum set temperature of additional
heating source
The voltage corresponding to the minimum
set temperature of additional heating
source
Enable or disable the TBH (Tank
booster heater) function: 0=NO,
1=YES
The temperature difference between T5
and T5S (the set water tank temperature)
for turning the booster heater off
The time for which the compressor has run
before startup of the booster heater
The ambient temperature for starting the
tank booster heater
Power input of TBH
Enable or disable the Solar function:
0=NO, 1=Only solar, 2=Solar and HP
(Heat Pump)
Solar pump (pump_s) control: 0=SL1SL2,
1=Tsolar
The temperature deviation for solar function
running
Enable or disable floor preheating:
0=NO, 1=YES
The set outlet water temperature during
first floor preheating
Running time for first floor preheating
Enable or disable floor drying: 0=NO,
1=YES
Temp-up days for floor drying
Days for floor drying
Temp-down days for floor drying
Outlet water temperature for floor drying
The start time of floor drying
The start date of floor drying
Enable or disable the auto restart of
cooling/heating mode: 0=NO, 1=YES
Enable or disable the auto restart of DHW
mode: 0=NO, 1=YES
The type of power input limitation
Define the function of the M1M2 switch:
0=remote ON/OFF, 1=TBH ON/OFF,
2=AHS ON/OFF
Enable or disable the smart grid:
0=NO, 1=YES
Control options of Port T1T2: 0=NO,
1=RT/Ta_PCB
Enable or disable the TBT: 0=NO, 1=YES
Select the function of P_X port:
0=Defrost, 1=Alarm
Percentage of operating units among all units
Time interval for determining the necessity
of unit loading/unloading
49
1
80
80
30
0
79
10
1
10
3
0
9
1
0
1
5
0
10
30
0
240
5
-5
50
2.0
0.0
20.0
0
0
2
0
0
1
10
5
20
0
0
1
25
25
35
72
48
96
0
0
1
8
4
15
5
3
7
5
4
15
45
30
55
00:00
0:00
23:30
Current
Current
31/12/2099 1/1/1 dd/mm/
date+1
date+1
1
0
1
1
0
1
1
1
8
0
0
2
0
0
1
0
0
1
0
0
1
0
0
1
10
10
100
5
1
60
1
°C
1
°C
1
V
1
V
1
/
1
°C
5
Minutes
1
°C
0.5
kW
1
/
1
/
1
°C
1
/
1
°C
12
Hours
1
/
1
Days
1
Days
1
Days
1
°C
1/30
h/min
yyyy
1
/
1
/
1
/
1
/
1
/
1
/
1
/
1
/
10
%
1
Minutes
V.1