Johnson AURUM R290 M Serie Guide D'utilisation page 105

Masquer les pouces Voir aussi pour AURUM R290 M Serie:
Table des Matières
Les langues disponibles

Les langues disponibles

t_T4_Fresh_H
T4HMAX
T4HMIN
dT1SH
Heating
dTSH
setting
Zone 1 H-emission
Zone 2 H-emission
Force defrost
AUTO
T4AUTOCMIN
mode
setting
T4AUTOHMAX
Water flow temp.
Temp.
Room temp.
type
setting
Double zone
Room thermostat
Room
thermostat
setting
Mode set priority
IBH function
dT1_IBH_ON
t_IBH_Delay
T4_IBH_ON
P_IBH1
P_IBH2
AHS function
Other
AHS_Pump_I
heat
Control
source
dT1_AHS_ON
t_AHS_Delay
T4_AHS_ON
EnSwitchPDC
GAS-COST
ELE-COST
The refresh time of climate-related curves
in heating mode
The maximum ambient operating
temperature in heating mode
The minimum ambient operating
temperature in heating mode
The temperature difference for starting the
unit (T1)
The temperature difference for starting the
unit (Ta)
The type of Zone 1 terminal for heating
mode: 0=FLH(floor heating)
1=FCU(fan coil unit), 2=RAD(radiator)
The type of Zone 2 terminal for heating
mode: 0=FLH(floor heating)
1=FCU(fan coil unit), 2=RAD(radiator)
Enable or disable the force defrost:
0=NO, 1=YES.
The minimum operating ambient
temperature for cooling in auto mode
The maximum operating ambient
temperature for heating in auto mode
Enable or disable the Water flow temp.:
0=NO, 1=YES
Enable or disable the Room temp.:
0=NO, 1=YES
Enable or disable the Double zone:
0=NO, 1=YES
The style of room thermostat: 0=NO,
1=Mode set, 2=One zone, 3=Double zone
Select the priority mode in Room
thermostat: 0=Heating, 1=Cooling
Select the mode of IBH (Internal backup
heater : 0=Heating and DHW,
1=Heating
The temperature difference between T1S
and T1 for starting the backup heater
The time for which the compressor has run
before startup of the first step backup heater
The ambient temperature for starting the
backup heater
Power input of IBH1
Power input of IBH2
Enable or disable the AHS (Auxiliary
heating source) function: 0=NO,
1=Heating, 2=Heating and DHW
Select the pump operating status when
only AHS runs: 0=Run, 1=Not run
The temperature difference between T1S
and T1 for starting the auxiliary heating
source
The time for which the compressor has run
before startup of the additional heating
source
The ambient temperature for starting the
additional heating source
Enable or disable automatic switch of heat
pump and auxiliary heating source based
on running cost: 0=NO, 1=YES
Price of gas
Price of electricity
48
0.5
0.5
6
25
20
35
-15
-25
30
5
2
20
2
1
10
2
0
2
0
0
2
0
0
1
25
20
29
17
10
17
1
0
1
0
0
1
0
0
1
0
0
3
0
0
1
0
(DHW=vaIid)
0
1
1 (DHW=
invalid)
5
2
10
30
15
120
-5
-15
30
0.0
0.0
20.0
0.0
0.0
20.0
0
0
2
0
0
1
5
2
20
30
5
120
-5
-15
30
1
0
0
0.85
0.00
5.00
0.20
0.00
5.00
0.5
Hours
1
°C
1
°C
1
°C
1
°C
1
/
1
/
1
/
1
°C
1
°C
1
/
1
/
1
/
1
/
1
/
1
/
1
°C
Minutes
5
1
°C
0.5
kW
0.5
kW
1
/
1
/
1
°C
Minutes
5
1
°C
1
/
3
0.01
price/m
price/
0.01
kWh
V.1