Status

Installer Checkout
Basic Settings
Menu
68
80
80
80
Backlight Enabled?
Yes
Zoning System Test
Linearize Dampers
Resume Schedule
Group 1
Away
75
72
71
71
36
Outside Temp Selection?
T957_O Low Refrigerant Pressure
Internet
Settings
Schedule
Status
Home
Away
status: Setting airflow
Water Heating
Refrigeration
Cooling to
34
65
85
70
OFF
BACK
BACK
BACK
Status
Furnace
AC/HP
Air Handler
Inside Temp : 77º
Outside Temp : 80º
Inside Rel. Humidity : 39%
Thermostat Mode : Off
Equipment Operating Status : Off
BACK
Installer Checkout

Furnace Status

Basic Settings
80
80
80
68
Backlight Enabled?
Yes
Current ->
Capacity :
0%
CFM :
0
Zoning System Test
Linearize Dampers
Resume Schedule
Group 1
Away
71
71
72
75
36
80º
0 º
Temperatures ->
Outside :
Supply :
Outside Temp Selection?
T957_O Low Refrigerant Pressure
Internet
Discrete Inputs ->
G :
off
Aux 1 :
off
Static Presure :
0.00 in.
Lo Heat
Hi Heat
Blower
Home
Away
Two Week Cycles :
0
0
0
status: Setting airflow
Two Week Hours :
0
0
0
Lifetime Cycles :
0
Refrigeration
0
0
Cooling to
Lifetime Hours :
0
0
0
70
34
65
85
OFF
BACK
BACK
BACK
Installer Checkout
Basic Settings

AC/HP Status

80
80
68
80
Backlight Enabled?
Yes
Unit Type :
AC
var-speed
2 tons
Zoning System Test
Linearize Dampers
Resume Schedule
Group 1
Away
71
75
71
72
36
Outside Temp:
68°
Outside Temp Selection?
T957_O Low Refrigerant Pressure
Internet
Hold-off Timer:
0
Utility Input : Disabled
Lo cool
Hi cool
Two Week Cycles :
1
1
Home
Away
Two Week Hours :
0
0
status: Setting airflow
Lifetime Cycles :
2
6
Refrigeration
Cooling to
Lifetime Hours :
0
2
34
65
85
70
OFF
BACK
BACK
BACK
AC/HP Status
Inverter Current Speed:
0 RPM
EXV Current Position:
96.0%
Superheat:
---
Coil Temp:
71.6 º
Suction Line Temp:
71.4 º
Suction Pressure:
203.6 PSIG
Liquid Line Temp:
-40.0º
Liquid Pressure:
0.0 PSIG
Subcooling:
0.0 º
BACK

Air Handler Status

Installer Checkout
Basic Settings
68
80
80
80
Backlight Enabled?
Yes
Current ->
Elec. Heat :
off
CFM :
0
Zoning System Test
Linearize Dampers
Resume Schedule
Group 1
Away
71
72
75
71
36
Temperatures ->
Supply :
--
Outside Temp Selection?
T957_O Low Refrigerant Pressure
Internet
Discrete Inputs ->
G :
off
Aux 1 :
off
Static Presure :
0.00 in.
Lo Heat
Hi Heat
Blower
Home
Away
Two Week Cycles :
0
0
20
status: Setting airflow
Two Week Hours :
0
0
0
Lifetime Cycles :
3
Refrigeration
3
112
Cooling to
Lifetime Hours :
0
6
115
34
85
65
70
OFF
BACK
BACK
BACK
Installer Checkout
Air Handler Status
Basic Settings
80
80
80
68
Backlight Enabled?
Yes
EXV Current Position ............ 58.2%
Zoning System Test
Linearize Dampers
Resume Schedule
Group 1
Away
71
72
75
71
36
EXV Current Superheat ......... 10.1°
Outside Temp Selection?
T957_O Low Refrigerant Pressure
Internet
Suction Line Temp ............... 61.1°
Saturated Suction Temp ......... 51°
Suction Pressure .................. 145 PSIG
Home
Away
status: Setting airflow
Refrigeration
Cooling to
70
65
85
34
OFF
BACK
BACK
BACK
> Return to Table of Contents
Tapping Menu > Status will display the connected communicating
Zone 3
Zone 4
!
equipment, thermostat mode and the equipment operating status.
21
Service
44%
61%
47%
44%
CFM: 840
54
Dining Room
Basement
UNITS
Selecting Furnace, Air Handler or AC/HP on the Status screen will display
each piece of equipment's current operating status and historical cycles and
run times.
ENERGY
Furnace Status (Menu > Status > Furnace)
Zone 3
Zone 4
!
RPM :
0
Furnace Status – Displays detailed furnace operation information including
Return :
0 º
21
Aux 2 :
off
two week and lifetime cycles, as well as run time hours.
Powered
61%
44%
44%
47%
0
CFM: 840
n/a
0
54
0 days
Dining Room
Basement
UNITS
AC/HP Status (Menu > Status > AC/HP)
Zone 3
Zone 4
!
AC/HP Status – Displays detailed AC/HP operation information including two
21
week and lifetime cycles, as well as run time hours.
44%
61%
44%
47%
CFM: 840
54
Dining Room
Basement
MORE
UNITS
(0%)
Air Handler Status (Menu > Status > Air Handler)
Zone 3
Zone 4
!
RPM :
0
Air Handler Status – Displays detailed air handler operation information
Return :
--
21
Aux 2 :
off
including two week and lifetime cycles, as well as run time hours.
Powered
44%
44%
61%
47%
4
CFM: 840
n/a
20
54
85 days
Dining Room
MORE
Basement
UNITS
Zone 3
Zone 4
!
21
47%
44%
61%
44%
CFM: 840
54
Dining Room
Basement
UNITS
EcoNet
Smart Thermostat User Guide
®