4.10 - Customising the system - Basic Menu
If necessary, users may select a basic menu which allows
modification of the control unit's basic parameters. To select the
basic menu proceed as described below.
WARNING: to be certain of accessing the NORMAL OPERATION
--
UP
DOWN
MENU
Press the MENU button for 1
second to access the basic
menu.
19
UP
DOWN
MENU
Press the MENU button
for 1 second to display the
parameter in order to save
the modified value, or MENU
quickly to quit the function
without saving.
PARAMETERS
TCL
1
Automatic reclosure time (0 = off)
Reclosing time after transit on PH1
ttr
2
(0 = off)
Sensitivity on obstacles
SEI
3
0 = Maximum impact force
10 = Minimum impact force
Motor speed during opening
1 = minimum
2 = low
SFO
4
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase
1 = minimum
2 = low
SSO
5
3 = medium
4 = high
5 = maximum
Motor speed during closing
1 = minimum
2 = low
SFC
6
3 = medium
4 = high
5 = maximum
Motor speed during closing deceleration phase
1 = minimum
2 = low
SSC
7
3 = medium
4 = high
5 = maximum
tCL
UP
DOWN
MENU
After accessing the BASIC
MENU, press the + and –
buttons to scroll through the
functions.
tCL
UP
DOWN
MENU
Press the + and – buttons to
scroll through the functions to
modify other parameters.
DESCRIPTION
display state, the starting point for accessing the basic menu,
press the MENU button twice.
Exampling of modifying a BASIC MENU parameter
20
UP
DOWN
MENU
To access the value modification
function, press the MENU
button for 1 second, until the
value starts to flash quickly.
--
UP
DOWN
MENU
Press the MENU button quickly
to quit the menu.
DEFAULT
0
0
3
4
1
4
1
19
UP
DOWN
MENU
Press the + and – buttons to to
modify the value.
MIN
MAX
UNIT
0
900
s
0
30
s
0
10
1
5
1
5
1
5
1
5
EN
33