Technical Data; Putting Into Operation; Maintenance And Cleaning - EINHELL DSS 260/2 Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Anleitung_DSS_260_2_11050_SPK1:_

4. Technical data

Release torque max.
Working range (max. thread size)
Permissible working pressure max.
Idle speed
Square drive
12,7 mm (1/2 inch)
Air consumption (6,3 bar)
Recommended hose diameter internal
Weight
Sound and vibration
Sound and vibration values were measured in
accordance with EN 792-6.
L
sound pressure level
pA
K
uncertainty
pA
L
sound power level
WA
K
uncertainty
WA
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Total vibration values (vector sum of three directions)
determined in accordance with EN 792-6.
Vibration emission value a
= 3.27 m/s
2
h
K uncertainty = 1.5 m/s
2
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect working
order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever
necessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Air quality
cleaned and oiled
Air supply
via conditioning unit with filter pressure reducer
and mist oiler
01.09.2010
9:16 Uhr
Compressor capacity
approx. 250 l/min. equivalent to a motor rating of 2.2
kW
312 Nm
M14
Work settings
6 bar working pressure set at the pressure
6.3 bar
reducer or filter pressure reducer
7000 min
-1

5. Putting into operation

115 l/min.
Ø 10 mm
Screw the plug-in nipple included in delivery into the
2.3 kg
air connection, having first wrapped 2 - 3 layers of
sealing tape around the thread. Attach the required
drive socket/bit to the square drive mount. Adjust the
direction of rotation on the guide lever.
R = reverse/release screw, F = forward/tighten
screw. Place the drive socket or bit on the nut or
screw head. Press the trigger. The air supply can be
adjusted by simultaneously depressing and turning
94 dB(A)
the air regulator. Mark 4 = max. torque, mark 1 =
3 dB
min. torque. The tool is connected to the air supply
105 dB(A)
by means of a flexible pneumatic hose with a quick-
release coupling. To get the best performance out of
3 dB
your screwdriver, use a pneumatic hose with an
internal diameter of LW 10 mm.

6. Maintenance and cleaning

Observance of the following maintenance
instructions will ensure that this quality tool gives you
years of troublefree service. Regular lubrication is
vital for the long-term, reliable operation of your
impact screwdriver. Use only special tool oil for this
purpose. You can choose from the following options
for lubricating the tool:
6.1 By mist oiler
A complete conditioning unit includes a mist oiler and
is fitted to the compressor.
6.2 By hand
Each time before you use your impactscrewdriver,
feed 3-5 drops of special tool oil into the air
connection. If the pneumatic tool has not been used
for several days, you must feed 5-10 drops of oil into
the air connection before you switch on. Keep your
pneumatic tool in dry rooms only.
6.3 Adjustment of resistance at the pivot arm (3)
By turning the adjustment screw (6) the resistance
when shifting the bolts (3) can be adjusted.
Seite 9
GB
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.389.10

Table des Matières