3.3. Cable mounting
For the choice of cable, chart 1 must be consulted.
The cable must run-off upwards from behind the drum.
The cable is allowed to run-off backwards horizontally from
underneath the drum with the WW series as well as with some of
the models in the VL series.
Be careful!
The brake does not work in the case of an incorrect cable run-
off.
The cable length must be of sufficient length to allow for 3
windings to remain on the drum when in the lowest position.
The cable is mounted by means of the fixed cable clamp.
WW2000-7500 ../D

3.4. Before use

The winch is fitted with a worm wheel gearing. To ensure a long
lifespan we recommend that the winch be run in before use.
Allow the winch to make approx. 5 drum rotations whilst loaded
with approx. 50% of the nominal load. Remove the protection
cover and using a brush, redistribute the grease over the worm
wheel and the worm gear. Replace the protection cover. The winch
is now ready for use.
Check before each use if the transfer is sufficiently greased.
This will prevent "galling" and overheating.
To enable the load pressure brake to function correctly, the winch must carry a minimum load of approx. 5% of
the nominal load.

3.5. Operating

The winches are suitable for manual operation only.
For the load to be hoisted, turn the crank clockwise.
For the load to be lowered, turn the crank anticlockwise.
3.6. ATEX
The winches with Ex rating can be used in ATEX zone 2 and 22.
The winches are marked as follows:
II 3GD T4