Power Interface Installation - LU-PH3-A
4. Referencing the Tape Light Solution Spec Submittal
(P/N
3691301) or Application Note #830 Lumaris Tape
Light Advanced Applications Guide
www.lutron.com, confirm the length and gauge of the
wire being installed from the power interface to the
wireless controller.
a. If wireless controllers are programmed in separate
zones and LED+ and LED- wires are in a T-tap
configuration (Option 2), it may result in subtle
interaction between controllers. Wiring in a homerun
configuration (Option 1) will have limited interaction
between controllers programmed in separate zones.
b. If wireless controllers are programmed in a single zone,
LED+ and LED- wires can be wired either in a homerun
or T-tap configuration (Option 1 or Option 2) without
concern of interaction between controllers.
c. Connect the necessary wires to the power interface
as shown in the wiring diagram. Power interface
terminals accept 12 AWG to 20 AWG
(4.0 mm
to 0.75 mm
2
terminals accept 14 AWG to 22 AWG
(2.5 mm
to 0.50 mm
2
Note: When wiring three controllers to the power
220 - 240 V~
interface, two of the three wireless controller LED+
and LED- wires need to be spliced together in the
power interface wiring compartment with a wire
connector and single wire run to the terminal block.
LED+ and LED- terminals on the power interface
accept one wire per terminal only.
5. Complete the installation of the wireless controller per the
following section, replace the top cover, then reapply power.
®
Lutron Tape Light Solution
(P/N
048830) at
) wires. Wireless controller
2
) wires.
2
Line / Hot
Neutral
Ground
LED
LED
D
L
N
(-)
(+)
Option 1: Homerun Wiring Configuration
Line / Hot
Neutral
Ground
LED
LED
D
L
N
(-)
(+)
Option 2: T-tapped Wiring Configuration
0.24 in
2.2 in-lb
(6 mm)
(0.25 N•m)
8
(continued)
}
120 / 277 V~
}
120 / 277 V~
www.lutron.com/support