Power Interface Installation - LU-PH3-B
4. For installations using a kit (RRL-MTK-RT-IN or
HWL-MTK-RT-IN), use the provided 2-conductor
wire for this step.
For all other installation types, or if more wire is needed,
reference the Tape Light Solutions Spec Submittal
(P/N
3691301) or Application Note #830
www.lutron.com for acceptable lengths and sizes for the
wire being installed from the power interface to the wireless
controller.
a. For wireless controllers programmed in separate
zones, wiring LED+ and LED- in a homerun
configuration (Option 1) will minimize interactions
between controllers. Wiring in a T-tap configuration
(Option 2) may result in subtle interactions
between controllers.
b. If wireless controllers are programmed in a single zone,
LED+ and LED- wires can be wired either in a homerun
or T-tap configuration (Option 1 or Option 2) without
concern of interaction between controllers.
c. Connect the necessary wires to the power interface
as shown in the wiring diagram. Power interface leads
and provided connectors accept 12 AWG to 20 AWG
(4.0 mm
to 0.75 mm
2
terminals accept 14 AWG to 22 AWG
(2.5 mm
to 0.50 mm
2
Note: Use the included wire connectors to
make all connections inside the integrated wiring
compartment.
5. Complete the installation of the wireless controller per the
Wireless Controller Installation
cover to contain all wire connections, then reapply power.
®
Lutron Tape Light Solution
(P/N
048830) at
) wires. Wireless controller
2
) wires.
2
section, replace the top
LED+
-
LED
LED+
-
LED
LED+
-
LED
Ground
Line/Hot
Neutral
Option 1: Homerun Wiring Configuration
LED+
-
LED
}
Ground
Line/Hot
Neutral
Option 2: T-tapped Wiring Configuration
6
(continued)
}
120 / 277 V~
120 / 277 V~
www.lutron.com/support