gas hoses, the regulator and all other components of the gas circuit.
It is recommended that the gas heater be inspected once a year by a professional.
Please follow the storage instructions when the gas heater is not to be used for
an extensive period.
TROUBLE SHOOTING
SYMPTOMS
1. Pilot will not light
automatically.
2. Pilot will not light
automatically but
points (a) to (e) are
satisfactory and the
pilot will light with a
match.
3. Heater will not remain
alight when pressure is
released from ignition
button.
4. After changing to
maximum position
with all three plaques
alight. One or more
plaques appear below
normal intensively.
5. Difficulty in cross ligh-
ting from position 1 to
position 2 or 3.
6. Smell of combustion.
7. No flame/No ignition
in winter
FAULT
No spark across electrode
gap.
Incorrect position of
spark in relation to pilot
gas flow.
Electro-magnetic calve
closes whilst heater is
alight.
Blocked jets.
Partially blocked supply
tube.
Air draught directed
away from first plaque.
Position of the pilot
flame.
Missing piece of ceramic
fireclay.
Butane is liquid instead
of gas and will burn
poorly below 7°C
REMEDY
(a) Ensure that pizeo-
electric switch is
functioning correctly.
(b) Check that electrical
lead is not damaged.
Re-position spark plug so
that spark jumps across
gas flow.
(a) Ensure that
thermocouple probe
is located in pilot
flame.
(b) Ensure good
connection between
thermocouple and
valve.
(c) Check thermocouple.
(d) Check electromagnetic
valve.
(a) Remove and clean
blocked jet.
(b) Remove supply tube,
remove jets and blow
through the tube.
(a) Change the location
of the appliance so
that it is not adversely
affected by air
draught.
(b) Position pilot so that
flame impinges across
bottom corner of 2nd
plaque as well as 1st
plaque.
Inspect perimeter of each
plaque and locate place
where some fireclay has
been displaced.
Repair with PYRUMA and
leave to set for approx.
24 hours.
1. Shake the gas cylinder
will often help
2. Replace gas cylinder
with a LPG mixture
with a higher Propane
content
4