Install the appliance for air extraction mode
For air extraction mode, use the seal and the
1.
acoustics filters.
Observe the instructions for the exhaust air pipe.
2.
→ Page 21
Securing the seal
Secure the enclosed seal on the flat duct elbow at
▶
a maximum of 5 mm from the edge.
→ Fig.
34
Establishing the piping
Insert the flat duct elbow into the outlet opening
1.
on the rear of the appliance.
→ Fig.
35
If required, install additional piping elements.
2.
Inserting the appliance into the worktop cut-out
Ensure that the connection cable is connected to
1.
the appliance.
Carefully insert the appliance into the worktop cut-
2.
out.
→ Fig.
36
Connecting the exhaust air pipe
Secure the exhaust air pipe to the flat duct bend.
1.
Establish the connection to the exhaust air open-
2.
ing.
Seal the joints appropriately.
3.
Inserting filters
Note: For circulating-air mode, insert the odour fil-
ters.
For air extraction mode, insert the acoustics filters.
Observe the filters' air flow direction.
1.
Insert two of the filters into the left and right of the
2.
appliance, and slide them forwards.
→ Fig.
42
Insert the other filters into the left and right of the
3.
appliance.
→ Fig.
43
Inserting grease filters
Insert the grease filter.
▶
→ Fig.
44
Establishing the connection to the power
supply
Observe the connection data on the rating plate.
1.
For 3 N, connect the cable to the mains socket in
2.
accordance with the figure.
→ Fig.
45
For 2 N, connect the cable to the mains socket in
3.
accordance with the figure.
→ Fig.
46
For 1 N, connect the cable to the mains socket in
4.
accordance with the figure.
→ Fig.
47
For 2 L/2 N, connect the cable to the mains
5.
socket in accordance with the figure.
→ Fig.
48
Note the colours of the cables.
6.
– BN: Brown
– BU: Blue
– GN/YE: Yellow and green
– BK: Black
– GY: Grey
If required, arrange the supplied wire end ferrules
7.
differently depending on the type of connection.
To connect two cables, if required, use a wire end
8.
ferrule.
Shorten the wires.
‒
Remove the insulation.
‒
Checking the function
Switch on the appliance.
1.
If
,
or
lights up, the appliance is not
2.
connected correctly. → "Checking and correcting
the electrical connection", Page 23
If no faults appear in the appliance's display, use
3.
the operating instructions to check that the ventila-
tion is working.
Checking and correcting the electrical connection
Disconnect the appliance from the power supply.
1.
Check whether the connection to the appliance
2.
and the building-side connection correspond to
the connection diagram in these installation in-
structions. → "Preparing the electrical connec-
tion", Page 20 → "Establishing the connection to
the power supply", Page 23
For 3 N, observe the following figure.
3.
→ Fig.
49
For 2 N, observe the following figure.
4.
→ Fig.
50
For 1 N, observe the following figure.
5.
→ Fig.
51
Switching the display for air extraction
mode
If required for the air extraction mode and the air
1.
recirculation mode, change the display of the elec-
tronic control in the basic settings.
Observe the basic settings section in the instruc-
2.
tion manual.
Removing the appliance
ATTENTION!
Tools may damage the appliance frame.
Do not prise out the appliance from above.
▶
Disconnect the appliance from the power supply.
1.
Remove the exhaust air duct or undo the circulat-
2.
ing-air connections.
Push out the appliance from below.
3.
fr
Contenu de la livraison
Après avoir déballé le produit, inspectez toutes les
pièces pour détecter d'éventuels dégâts dus au
transport et pour vous assurer de l'intégralité de la li-
vraison.
→ Fig.
1
Code QR vidéo concernant l'installation
Vous trouverez ici le code QR pour la vidéo concer-
nant l'installation.
→ Fig.
2
Dimensions de l'appareil
Vous trouverez ici les dimensions de l'appareil
→ Fig.
3
Cotes d'encastrement coudes de conduit
plat
Vous trouverez ici une vue d'ensemble des cotes
d'encastrement des coudes de conduit plat.
Vue latérale :
→ Fig.
, → Fig.
, → Fig.
4
5
Vue de face :
→ Fig.
7
Variantes d'installation
Vous trouverez ici une vue d'ensemble des diffé-
rentes variantes d'installation.
6
23