board and temperature probe. It is recommended to have one of the ventilation grilles at the CPU height to
facilitate its cooling and revision.
A
Lateral wall 'flammable.
A
Lateral wall 'not flammable.
B
Back of the stove.
C
Open door and stove depth.
D
Cover.
q
Ventilation grill. OBLIGATORY.
Isolated output gas pipe within the
w
socket. OBLIGATORY
4.14. It is necessary to screw down 2 angle brackets to the floor (q) and then secure them with the screws from
the front (w).
q
Angle brackets fastened to the floor.
Distance between angles:
w
ECO I insert:
ECO II insert:
Fit the stove frame to the angles and
e
place the decorative cap.
Stand-off distances are the same for all models.
4.15. Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.16. The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove's output. It is mandatory to install at least
two metres in length vertically to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1 metre; greater lengths mean ash, condensation or corrosion
may build up in this area.
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is
recommendable to install an uninterruptible power supply (UPS) which we have available as an option. This
apparatus only feeds the exhaust vent.
4.17. Distances from doors, windows, ventilation grids or air input to the house or building:
≥ 650 mm
≥ 420 mm
≥ 80 mm
See dimensions
≥ 500 mm
Effective area
2
456 cm
Ø80mm.
RECESSING THE ECO I INSERT STOVES.
2 units
654 mm
646 mm
2 units
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
x 2
32
Drawing 5
Drawing 6