en - Original instructions
7.9 The electric pump stops, and
then rotates in the wrong direction
Cause
There is a leakage in
one or both of the
following components:
The suction pipe.
The foot valve or
the check valve.
There is air in the
suction pipe.
7.10 The pump starts up too
frequently
Cause
There is a leakage in
one or both of the
following components:
The suction pipe.
The foot valve or
the check valve.
There is a ruptured
membrane or no air
pre-charge in the
pressure tank.
7.11 The pump generates too much
noise
Cause
Remedy
Pump
Reduce the required flow
cavitation
rate by partially closing the
on-off valve downstream
from the pump. If the
problem persists check the
operating conditions of the
pump (for example height
difference, flow resistance,
liquid temperature).
The motor
Contact Xylem or the
bearings are
Authorised Distributor.
worn.
There are
Contact Xylem or the
foreign
Authorised Distributor.
objects
inside the
pump
Impeller rubs
Contact Xylem or the
on the wear
Authorised Distributor.
ring
Coupling
Check the coupling
misaligned
alignment.
Flexible
Contact Xylem or the
elements of
Authorised Distributor.
the coupling
worn
Contact Xylem or the Authorised Distributor
with regard to any situations not covered here.
32
Remedy
Repair or replace
the faulty
component.
Bleed the air.
Remedy
Repair or replace
the faulty
component.
See the relevant
instructions in the
pressure tank
manual.