C9 High Motor
1. Water supply valve not closed
Temp. Compressor
C20 Low Sensor
1. Pressure signal from pumptop sensor, out of range
Signal P-Pumptop
C21 Low Sensor
1. Temparature signal from pumptop, sensor, out of range 1. Press "off" button
Signal T-Pumptop
C22 Low Sensor
1. Pressure signal form inlet sensor, out of range
Signal P-Air
C23 Low Sensor
1. Temperature signal from inlet sensor, out of range
Signal T-Air
C25 Low Sensor
1. Signal from flow sensor, out of range
Signal flow
C30 High Sensor
1. Pressure signal from pumptop sensor, out of range
Signal P-Puumptop
C31 High Sensor
1. Temperature signal from pumptop sensor, out of range
Signal T-Pumptop
C32 High Sensor
1. Pressure signal from inlet sensor, out of range
Signal P-air
C33 High Sensor
1. Temperature signal from inlet sensor, out of range
Signal T-Air
C35 High Sensor
1. Signal from flow sensor, out of range
Signal flow
C40 Sensor Load
1. Supply voltage for pumptop sensor too low.
Pumptop Sensor
2. Pumptop sensor using too much current
C41 Sensor Load
1. Supply voltage for inlet sensor too low
Air sensor
2. Inlet sensor using too much current
C43 Sensor Load
1. Supply voltage for flow sensor too low
Flow sensor
2. Flow sensor using too much current
1. Secure sufficient air supply to
the valve.
2. Contact your local service
technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
1. Press "off" button
2. If error reoccurs, contact your
local service technician.
23