PRODUCT DIMENSIONS
ZVC48
The custom canopy must be sized to fit the insert
sleeve. Construct the canopy with an opening
that is:
38-3/4"W x 13-3/16"D
The opening must be constructed of 3/4" thick
material to allow the sleeve locking clips to
engage.
The Supplied Liner
3-7/8"
7-1/2"
4"
Front side
The stainless steel liner is shipped with each hood
insert. This non-combustible liner protects the
underside of the canopy.
Custom Liner
If you are not using the supplied liner, you may
construct a custom non-combustible liner. Use the
supplied liner as a template. The opening must be
38-3/4"W x 13-3/16"D. 3/4" thick material must
surround the opening to allow the sleeve locking
clips to engage. The insert sleeve inside the cabinet
should be positioned 1/2" from the rear wall so
that the center of the 8" duct is 5-1/2" from the
rear wall.
Design Information
*Opening
46-1/2"
Dimensions and Specifications (in inches)
Outside Dimensions
The Insert Sleeve
13"
1/2"
1/2"
A 1/2" wide flange surrounds the outside edge of
the insert sleeve.
21-1/4"
Remote Location for the Control
The control may be removed from the hood
and installed into a wall or countertop. A 30-ft.
length of wire is supplied to accommodate most
installations. A blanking plate covers the opening
when the controls are removed.
The overall size of the control is 4-1/4" wide and
2-1/4" deep.
1-11/16"
We recommend that the cutout in granite or other
hard surfaces be made before the countertop is
installed.
8
39-1/2"
29-1/2"
Front side
38-1/2"
3-11/16"
Control cutout
14"
14"
1/2"
13"
1/2"