5.2. Environment

Place the units in a place that is accessible for installation and maintenance work and which allows
operating through the TFT display.
The air vents and part of the power module can reach high temperatures. Do not place any material
nearby which is sensitive to high air temperatures.
Avoid corrosive environments that may affect its proper operation. Do not install the unit in areas
classified as ATEX.
Never place any object on top of the unit.
It is recommended to place the units under a cover that protects them from direct radiation, placing the
front part facing north in the Northern Hemisphere and facing south in the Southern Hemisphere.

5.3. Environmental conditions

Environmental conditions must be taken into account when choosing the location of the unit.
Maximum relative humidity without condensation
The operation of the unit at temperatures greater than 50 ºC should only occur occasionally and not permanently. Ingeteam is not
(1)
responsible for the consequences to the unit resulting from operating it at temperatures higher than 50 ºC.
At altitudes higher than 1000 m, please contact Ingeteam.
(2)
It should be borne in mind that moderate condensation may occasionally occur as a consequence of temperature
variations. For this reason, apart from the unit's own protection, it is necessary to monitor these units once they
have been started up on sites where the conditions described above are not expected to be present.
In the event of condensation, never apply voltage to the unit. To remove condensation apply a flow of hot air at a
maximum temperature of 60 ºC.
INFO
Ingeteam does not guarantee the proper operation of the equipment if the operation conditions for which it has
been designed are not fulfilled.
22
Environmental conditions
Minimum temperature
Minimum surrounding air temperature
Maximum operating temperature
Altitude
Preparation for installing the unit
-20 ºC
-20 ºC
60 ºC
(1)
95%
2000 m
(2)
ABT2012IQM01_B- Installation and Operation Manual