Switching bet-
ween the wire
feeders
-
Fig.8
Important! After having switched over to the other wire feeder, make use of the initiali-
sation phase for adapting the settings for the other wire feeder.
Warning! An electric shock can kill you. For simultaneously connected welding
torch / electrode holder stick to the following instructions: the electrode of the
welding torch / electrode holder - also if not used - is alive.
-
Take care of sufficiently insulated storage of the welding torch / electrode
holder, which is not used.
-
Prevent contact between the electrode of the welding torch/ electrode holder,
which is not used, and persons or objects.
Connect mains connection and switch mains switch in position "On".
Selector switch for internal / external wire
feeder
Note! Irrespective of the wire feeder selected, the settings chosen for the
recent welding process apply.
Use the selector switch for switching
between the wire feeders.
-
Selector switch in position "INT." ...
the wire feeder integrated in the TPS
2700 Duo power source is activated
-
Selector switch in position "EXT." ...
the external wire feeder is activated
8
Note! After having switched over
to the other wire feeder, the
corresponding welding torch is
not immediately ready for wel-
ding.
-
Wait an initialisation phase of
approx. 10 seconds