Wireless Rf Outside Sensor (Inst:  System Parameters: Input, "Ouse"); Inputs Functions (In1 & In2); Input1 - Selfio FlowBox-HC Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wireless RF outside sensor (Inst:  System parameters: Input, "OUSE").
5.4
As an option you can plug in a wireless RF outside sensor room thermostat to the ClimaticControl-HC. This solu-
tion is very interesting in rehabilitation, to avoid wires trough the wall, in a building management with several CC-
HC, in this case only one outside sensor can be installed to manage all the building.
Radio alarm: RF supervising function.
If the ClimaticControl-HC is installed with RF thermostat(s) and there is no radio signal received during more than 2
hours, a display alarm will be activated,the backlight and the small RF antenna logo
1. To stop the alarm, maintain the (OK) button pressed for about 10 seconds.
2. Check the batteries of the RF thermostat(s) or outside RF sensor. Please replace them if exhaust-
ed.
3. Check the position in which the antenna was installed. It must be installed in vertical position.
Installation in or on a metal body can abate the power of radio transmission. Minimize the distance
to the RF thermostat.
If radio alarm is displayed:
- Due to the wireless thermostat, the regulation will continue to work as an installation without thermostat (no com-
pensation).
- Due to the Wireless outside sensor, the regulation will continue to work with the last value received from the out-
side sensor.
5.5
Inputs functions (In1 & In2)
If no wired thermostat is installed in the house, you will have the possibility to use the two available inputs of your
ClimaticControl-HC for different functions (Inst:  System parameters: Input, "In1 & In2").
5.5.1

Input1

Inst:  System parameters: Input, "HC"
You could use the input 1 to connect the an external signal which give the Heating or Coling working mode
of the installation (This signal could be done directly by a reversible input).
Inst:  System parameters: Input, "Aqu"
1/ You could use the input 1 to connect the an imersion thermostat witch schould be placed in a storage
tank. In Heating mode this immersion thermostat will be use to switch off the circulation pump (Pump1) to
avoid cold water circulation in the circuit if the storage tank is discharged. (This solution is generally use
when solid wood burner is installed)
2/ You could also use this input to have a priority on domestic hot water.
In this case the pump of the heating circuit will be stopped to keep the priority on the domestic hot water.
Note:
- The heating output will stay activated even if the aquastat have stopped the circulation pump.
- To avoid problem in cooling mode, if the storage tank is filled with cold water (by heat pump...) the
aquastat function will be automatically desactivated.
WIRELESS OUTSIDE
SENSOR
The wireless outside sensor can be used only with the 433,92Mhz frequency
RF outside sensor initialization to the Controller:
SYSTEM PARAMETERS MENU, section
(Inst:  System parameters: "OUSE")
9
GB
fig.9
radio will blink.