4

Display

1:
Operating modes
2:
Keyboard is locked
3:
Service Installation Menu
4:
Manual operation / program override active
(display of temperature offset)
5:
a) display temperature (°C / °F)
b) display time (12 h / 24 h)
6:
Type of temperature displayed
a) Water temperature
b) Outside temperature
c) Room temperature (if RF room thermostat con-
nected)
7:
Program graphic of the current day
Comfort temperature
Reduced temperature
8:
Pump indicator
9:
Demand indication
Heating /
Cooling /
10: Current day of the week (1 = Monday; 7 = Sunday)
11: RF reception indicator
12: a) Symbol temperature indication in °C / °F
b) Symbol AM / PM if 12 h mode
13: a) Outside temperature (°C / °F)
b) Time (12 h / 24 h)
14: Mixing valve activity indicator
 Valve actuator is opening
 Valve actuator is closing
5

Installation and Electrical connections

5.1

ClimaticControl-HC Installation

The ClimaticControl-HC can be installed directly on a solid base (e.g. a wall). For this purpose the front panel of the
ClimaticControl-HC must be removed (fig. 4a) and the back section should be fastened using appropriate screws
and pins (these are not included in the scope of supply) (fig 4b) Fix the climatic control HC on a plane surface
(wall...)
If the ClimaticControl-HC has been factory fitted with cables for connecting to a pump, valve drive, temperature
limiter, sensors etc., take care not to damage or crack the cables during the installation. Furthermore these cables
should not subjected to any tensile stress during installation. The cables will be fixed by means of the device for
strain relief at the ClimaticControl-HC.
If the ClimaticControl-HC is delivered together with a hydraulic control unit (for example FRG or FlowBox) and if it is
not attached to that unit by any installation plate or support, it should be installed next to that unit.
Pay attention to the correct connection of the cables if the ClimaticControl-HC is not installed directly on a hydraulic
control unit but at some other place for the reason of better access.
Refer to the directions about this in section 5.2 Electric connections.
Humidity function
(optional).
2
3
4
5
6
7
8
9
Details Pos. 6
a
b
c
Dimensions
Fig.3
5
1
86 mm
47 mm
OK
GB
10
11
12
13
6
14
Fig.2