Festo DNCV Série Notice D'utilisation page 24

Masquer les pouces Voir aussi pour DNCV Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
DNCV-...
Fitting pneumatic components
Check whether non-return valves type HGL-QS-... are required here.
S
If there is a drop in pressure on a system where the cylinder is mounted in a
vertical position, non-return valves will ensure that the mass remains in the
position reached and does not slide down.
Remove the adhesive labels on the compressed air ports.
S
Connect the tubing for the pneumatic
S
ports of the DNCV-... as follows:
– connection aA: Compressed air supply
– connection 1: Exhaust port (pre-fitted
silencer or ducted exhaust).
Fitting electric components
Warning
S Use only power units which guarantee reliable isolation of the operating volt-
ages as per IEC 742/EN 60742/VDE 0551 with at least 4 kV isolation resis-
tance (Protected Extra Low Voltage PELV).
Switch power packs are permitted, providing they guarantee reliable isola-
tion in accordance with EN 60950/VDE 0805.
Warning
User-prepared cables reduce the functional reliability.
S Use only a connector socket and cable as specified in the chapter
"Accessories."
In this way you can be sure that the cable is not longer than 30 m (protection
from input offset currents induced by electromagnetic interference fields).
24
1
Fig. 9
Festo DNCV-... 0207a English
aA

Publicité

Table des Matières
loading

Table des Matières