Final Check; Service; Before Calling Service; Product Data Plate - Bosch NGM30 Guide D'installation

Masquer les pouces Voir aussi pour NGM30:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Final Check

Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow tip.

Service

Before Calling Service

If the ignitors do not spark or the "on" indicator lights do not
glow, check the power source to see if a fuse has blown or
if the circuit breaker has tripped.
Refer to the Warranty in the Use and Care Manual. See
Use and Care manual for troubleshooting information.

Product Data Plate

The data plate shows the model and FD (product's unique
identifier for customer service) number of your cooktop. It is
located on the underside of the rough-in box, underneath
the cooktop.
English 8
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or
mostly yellow, verify that the regulator is set for the
correct fuel. After adjustment, retest.
Some yellow streaking is normal during the initial start-
up. Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.
Figure 11: Checking Flame Characteristics
Data Plate
Keep your invoice or escrow papers for warranty validation
if service is needed.
Figure 12: Data Plate Location