Front Panel - LD Systems LD WILDTHANG 200 Manuel D'utilisation

2 x 220 w 4 ohm
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
1
POWER LED (GREEN)
The power LED lights up when the amplifier is turned on and indicates that it is ready for operation.
2
3
SIGNAL LED CHANNEL A / CHANNEL B (CHA / CHB; GREEN)
These LEDs indicate that there is a signal present and the amplifier is working.
4
5
CLIP LED CHANNEL A / CHANNEL B (CHA / CHB; GREEN)
The CLIP LEDs light up if the input voltage is too high.
6
7
PROT LED CHANNEL A / CHANNEL B (CHA / CHB; YELLOW)
These LEDs light up in the following four situations:
1. During the first few seconds after the amplifier is turned on or off Ausschalten des Verstärkers
2. When the amplifier (power amplifier) overheats
3. In the event of a technical malfunction: DC voltage fault protection
4. In the event of a short circuit at the output
8
9
INPUT GAIN CONTROL (VOLUME) CHANNEL A / CHANNEL B (CHA / CHB)
These knobs are used to adjust the input gain of the amplifier.
10
POWER SWITCH (POWER)
It takes approx. 3 - 4 seconds after power-on until the amplifier is ready for operation (soft start function).
10
2
4
6

FRONT PANEL:

8
1
9
7
5
3
5