Saey Scope Guide D'installation Et D'utilisation page 55

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation of the combustion air inlet
For more accurate control of the burning up of the fuel, an additional combustion air inlet is located
underneath the grate, against the rear wall inside the appliance. This inlet can be adjusted with the aid
of the control handle, as indicated in the illustration. In position "0" the cast-iron knob is fully recessed in
the sidewall, and in position "l" it is fully extended (see: division on inner surface of the side wall).
When burning coal and anthracite, the lower lever must be pulled out completely.
Removing the ash pan before cleaning
Depending on the quantity of ash, the ash pan must be emptied regularly – certainly before the level of
the ash reaches the grate. To do this, hook the pin of the control handle into the front plate of the ash
pan and carefully pull it out of the appliance so that it can be emptied.
Removal of the grates
After regular use (depending on the quantity of ash), the grates must be cleaned thoroughly. To do this,
remove the standing grate on the front from its supports and then remove the wood grate from the
frame. After the ash pan has also been removed from the appliance and the appliance has cooled down
completely, it can be cleaned with a vacuum cleaner.