Festo DNCI-32 Notice D'utilisation page 25

Masquer les pouces Voir aussi pour DNCI-32:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
DNCI
If the DNCI is used as a measuring cylinder:
Observe the commissioning instructions for the measuring signal amplifier
S
used.
1. Push the piston rod at first into a mechanical end position.
2. Screw the one−way flow control valves into both compressed air connections
at first completely (as supplied from the factory),
then open them up again one turn.
The DNCI will then move slowly over the complete positioning path.
3. Slowly pressurize the compressed air connection of the mechanical end
position.
4. Start a test run.
5. Unscrew the one−way flow control valves until the desired speed is reached.
6. Conclude the test run.
If the DNCI is used with electronic control:
Please note
Special commissioning regulations apply to the electronic control of the DNCI:
S Observe the instructions in the manuals for the positioning controller when
commissioning.
Start a test run (at the lowest permitted pressure).
S
Check to see if the settings on the DNCI or on the controller need to be modi
S
fied:
Reference stop
Speed
Switching points
Movement sequence
Conclude the test run.
S
Festo DNCI 0810b English