3-2-1-7 Saving Function Switch On/Off Function (S12):Default : OFF
The saving mode will be triggered if the output load <20W @10seconds.
3-2-2 Status LED indicator:(reference F)
Icon
Description
Battery Input voltage indicator
Alarm indicator
Status
Indicator
Solid ON
Green
Slow Blink
Fast Blink
Solid ON
Orange
Slow Blink
Fast Blink
Red
Solid ON
18
Saving function
OFF
ON
Table 11
Saving function switch On/Off function definition
LED
Off
Normal
(12V: 11.5 ~ 15.0V)
(24V: 23.0 ~ 30.0V)
Off
Battery Low voltage
(12V:11.0 ~ 11.5V)
(24V:22.0 ~ 23.0V)
Battery High voltage
(12V:15.0 ~ 15.5V)
(24V:30.0 ~ 31.0V)
Off
Battery Under voltage
(12V: < 11.0V)
(24V: < 22.0V)
Battery Over voltage
Icon
Description
Output Load indicator
Charger Stage indicator
Table 12
LED indicator
Normal
(0~100%)
Over load
(100%-115%)
Over load (>115%)
S12
OFF
ON
Inverter mode
Normal status
Float mode
Over Temperature
Equalization mode
Protection
Under Temperature
Active mode
Protection
Inverter mode
Phase or Frequency
Absorption mode
Failure
Grid Over / Under
Bulk mode
Voltage Protection
Grid Over Current
Protect
Inverter mode
Over Load /
Short Circuit
Protection