EN
3-2-1-3 AC Input Current Limit Select (S4,S5,S6):
SC 1200 / 2000 Default: 15A/10A ; SC3000 Default: 30A/16A
100~120V / 200~240V
3-2-1-4 Battery Type Select Function(S7,S8):Default : GEL
3-2-1-5 Charger current Select Function(S9,S10):Default : 100%
3-2-1-6 DC Source Output On/Off Function (S11):Default : OFF
AC Input Current
3A / 2A
6A / 4A
9A / 6A
12A / 8A
15A / 10A
20A / 12A
25A / 14A
30A / 16A
:
Table 7
Gemini SC series Input current limit select function definition
Battery Type
GEL
Flooded
AGM
Customer
:
Table 8
Battery types select function definition
Charger Current (%)
25%
50%
75%
100%
:
Table 9
Charger current select function definition
ESB function
OFF
ON
:
Table 10
DC source output On/Off function definition
S4
S5
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
S7
OFF
ON
OFF
ON
S9
OFF
ON
OFF
ON
S11
OFF
ON
S6
OFF
OFF
OFF
OFF
ON
ON
ON
ON
S8
OFF
OFF
ON
ON
S10
OFF
OFF
ON
ON
17