Télécharger Imprimer la page

Cotek Gemini SC Serie Mode D'emploi page 16

Publicité

Les langues disponibles

Les langues disponibles

EN
A
AC Output
B
AC Input
Chassis
C
ground
14
Two 3/4 inch knockouts provided with cable-clamp strain reliefs to allow and hold the AC
input and output field wiring.
*If the grid power use GFCI or RCD socket, please set up the input current limit following
their max current limitation for avoiding the risk of socket damage.
Model No.
SC1200-112
SC1200-124
SC1200-212
SC1200-224
SC2000-112
SC2000-124
SC2000-212
SC2000-224
SC3000-112
SC3000-124
SC3000-212
SC3000-224
This connection is used to tie the exposed chassis of the inverter to the DC grounding
system. This terminal accepts CU/AL conductors from #14 to #2 AWG (2.1 to 33.6 mm2).
Front panel
AC IN AWG
AC OUT AWG
30A/10AWG
30A/10AWG
30A/10AWG
30A/10AWG
16A/12AWG
22A/10AWG
16A/12AWG
22A/10AWG
30A/10AWG
30A/10AWG
30A/10AWG
30A/10AWG
16A/12AWG
26A/10AWG
16A/12AWG
26A/10AWG
30A/10AWG
50A/8AWG
30A/10AWG
50A/8AWG
16A/12AWG
31A/10AWG
16A/12AWG
31A/10AWG
GROUNDING AWG
30A/10AWG
30A/10AWG
22A/10AWG
22A/10AWG
30A/10AWG
30A/10AWG
26A/10AWG
26A/10AWG
50A/8AWG
50A/8AWG
31A/10AWG
31A/10AWG