Main switch
DIP switch
E
F
Function LED
AC input
G
breaker
WARNING!
The ground wire offers protection only if the cabinet of the unit is
connected to the safety ground. Connect the chassis ground.
Terminal to the hull or the chassis.
Refer to local regulations on these issues!
For safety purposes the neutral conductor (N) of the AC output must be connected to the
earth (PE / GND) when the unit is in inverter operation. When utility power is available on
the AC input, and the unit is in charger mode, this connection must be disabled again.
In some applications automatic connection between the neutral conductor (N) and earth
(PE / GND) is not required or acceptable. Therefore the automatic connection between the
neutral conductor (N) and earth (PE / GND) is enabled by default.
The switch for 1.Power ON 2.Power Off 3.Remote Mode.
Dip Switch
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
From left to right is "Battery voltage"', "AC output load", "Charger stage", "System status"
*For details, refer to 3-2-2
1xx : 30 Amp, 2xx : 16 Amp
Table 4
Gemini SC series front panel introduction
Function
Output Voltage Select
(refer to 3-2-1-1)
Frequency Select
(refer to 3-2-1-2)
AC Input Current Limit Select
(refer to 3-2-1-3)
Battery Type Select
(refer to 3-2-1-4)
Charger Current Select
(refer to 3-2-1-5)
DC Source on/off
(refer to 3-2-1-6)
Saving Function on/off
(refer to 3-2-1-7)
15