SAFETY DEVICES
Photocells
Configure contact CX or CY (NC), safety input for photocells.
See F2 (input CX) or F3 (input CY) in:
- C1 reopening during closing. When the gate is closing, opening the contact triggers the inversion of movement until the gate is fully open again;
- C2 closing during opening. When the gate is opening, opening the contact triggers the inversion of movement until the gate is completely closed.
- C3 partial stop. Stopping of the gate, if it is moving, with consequent automatic closing (if the automatic closing function has been entered);
- C4 obstruction wait. Stopping of the gate, if it is moving, which resumes movement once the obstruction is removed.
 If contacts CX and CY are not used they should be deactivated during programming.
RX
10 11 TS 1 2 3 3P 4 5 7 CX CY
Photocells (safety test)
At each opening and closing command, the control board checks the efficacy of the safety devices (such as, photocells).
A malfunction will inhibit any command and the display will show the Er4 wording.
Enable function F5 in programming.
RX
10 11 TS 1 2 3 3P 4 5 7 CX CY
DIR
DELTA-S
DIR
DELTA-S
TX
RX
TX
RX
DELTA
10 11 TS 1 2 3 3P 4 5 7 CX CY
DELTA
10 11 TS 1 2 3 3P 4 5 7 CX CY
TX
TX