CONTROL DEVICES
WARNING! For the system to work properly, before fitting any snap-in card (e.g. the AF R800), you MUST CUT OFF THE MAIN POWER
SUPPLY and remove any batteries.
10 11 TS 1 2 3 3P 4 5 7 CX CY
A B S1 GND
Keypad selector.
STOP button (NC contact). For stopping the gate while excluding automatic
closing. To resume movement either press the control button or any other
control device.
 Activate the F1 programming function. If the button is no used, leave
this function deactivated.
OPEN ONLY function from control device with NO contact.
Warning: in MAINTAINED ACTION mode, the control device must be connected
to 2-3.
PARTIAL OPENING function from control device (NO contact)
ONLY CLOSE function from control device (NO contact).
Warning: in MAINTAINED ACTION mode, the control device must be connected
to 2-4.
OPEN-CLOSE-INVERT (step-by-step) function from control device (NO contact).
Alternatively, from the functions programming you can activate the single
command OPEN-STOP-CLOSE-STOP (sequential).
See function F7.
Antenna with RG58 cable for remote control.
Connector for the AF (AF43S or AF868) card, for
controlling the gate via a transmitter.
BLACK
RED
Connector for the R700 card (for using the transponder
selector or the card reader) or for the R800 card (for using
the keypad selector).
 To set the type of selector, see function F14
Transponder or card reader.

Publicité

loading

Ce manuel est également adapté pour:

Bk serieBks22ale