FASTENING THE OPERATOR
Once adjusting is complete, fasten the gearmotor to the plate using the plates and nuts.
ESTABLISHING THE LIMIT-SWITCH POINTS
For opening:
- open the gate; 
- fi t the opening limit-switch tab onto the rack until the micro switch activates (spring) and fasten it using the grub screws. 
~ 20
For closing:
- close the gate; 
- fi t the closing limit-switch tab into the rack until the micro-switch is activated (spring) and fasten it using the grub screws. 
2 2
1
2
1