Télécharger Imprimer la page

Kohler K-1697 Guide D'installation page 8

Masquer les pouces Voir aussi pour K-1697:

Publicité

Les langues disponibles

Les langues disponibles

Maintain a 12" (30.5 cm) minimum
space around the units.
5. Install the Steam Generators
WARNING: Risk of property damage. Allow a minimum of 12" (30.5 cm) of air space around the
steam generators at all times. This provides an area for the heat generated by the units to dissipate.
NOTICE: For optimum performance, install the steam generators as close as possible to the steam heads.
The steam generators must be installed within 25' (7.62 m) of the steam head.
Install the desired drain pan at the steam generator location.
IMPORTANT! The support blocks should be constructed of heat resistant material.
Position support blocks so the steam generators will have 3/4" (1.9 cm) of clearance from the drain
pan.
Position the steam generator on the drain pan.
1053777-2-D
12"
(30.5 cm)
Drain Pan
Inlet
Steam Outlet
Pressure Relief Valve
Control Cable
Input
8
Kohler Co.

Publicité

loading

Ce manuel est également adapté pour:

K-1716