Function Of The Buttons; Reference Run; Program Execution - IDC Mikro Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

A P P L I C A T I O N A N D O P E R A T I O N
6.2

Function of the buttons

E N
Fig. 10
Buttons
Key
Operation
button [A]
Service but-
ton [B]
Tab. 4
Instead of with the buttons, these func-
tions can also be actuated via the soft-
ware.
34
A
B
Door shut
Door open
Starts or stops the
Activates or

reference run;

deactivates
starts or stops the
the extrac-
current program;
tion system
activates or deac-
tivates the control
position; activates
the change posi-
tion for the blank
holder
Interrupts the cur-
Activates or
rent program; acti-
deactivates
vates the service
the sealing
position; activates
air
the tool-changing
position; starts a
cleaning run of the
inspection window
6.3
Reference run
After switching on, a reference run must be car-
ried out to determine the mechanical zero points.
Operation button [A] flashes.
To start the reference run:
▷ Briefly push operation button [A].
The reference run is started. Operation button
[A] lights up.
The reference run can be stopped:
▷ Briefly push operation button [A].
The reference run is stopped. Operation button
[A] flashes.
To continue the reference run:
▷ Briefly push operation button [A].
The reference run is continued at the position
where it was stopped. Operation button [A]
lights up.
On completion of the reference run, the machine
returns to the starting position. Operation button
[A] goes out.
6.4

Program execution

Before executing a program, it must first be
loaded (see CAM Software).
▷ Briefly push operation button [A].
The program is started. Operation button [A]
lights up.
The program can be stopped:
▷ Briefly press operation button [A] or service
button [B].
-or-
▷ Open the door.
The program is stopped. Operation button [A]
flashes.