• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. A single wire must have a minimal
cross section in accordance with the table
below. Speak to your local Service Centre.
The connection cable may only be
replaced by a qualified electrician.
WARNING!
All electrical connections must be made
by a qualified electrician.
CAUTION!
Connections via contact plugs are
forbidden.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
N
L
220 - 240 V~
5x1,5 mm²
Green - yellow
N
Blue and blue
L1
Black
L2
Brown
3.4 Assembly
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the
appliances.
220-240 V~
Two-phase connection: 400 V2N~
5x1,5 mm² or 4x2,5 mm²
N
L1
L2
CAUTION!
Do not connect the cable without cable
end sleeve.
One-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove a part of the insulation of the
brown and black cable ends.
3. Connect the ends of black and brown
cables.
4. Apply a new wire end sleeve on the
shared wire's end (special tool required).
NL connection
1. Remove the cable end sleeve from blue
wires.
2. Remove a part of the insulation of the
blue cable ends.
3. Apply a new wire end sleeve on the each
wire's end (special tool required).
400V 2~N
One-phase connection: 220
- 240 V~
5x1,5 mm² or 3x4 mm²
Green - yellow
Blue and blue
N
Black
L
Brown
N
L1
L2
Green - yellow
Blue and blue
Black and brown
ENGLISH