BRS-CC
Ambient temperature
Relative humidity
Tab. 1
Ambient conditions during operation
Storage in a closed environment, ambient temperature
Ambient temperature for shipment
Relative humidity
Tab. 2
Ambient conditions for transport and storage
Weight
Dimensions (L × W × H)
Protection type in accordance with DIN 40050
Protection class in accordance with DIN EN 61140
Tab. 3
General information
NOTICE
• To guarantee the maximum power and useful life of the torch cleaning station, operate it with clean, lubricated air.
Compressed air connection
Hose diameter
Nominal pressure
Working pressure
Quality of compressed air (ISO 8573-1:2010)
Tab. 4
Pneumatic distributor block
Pneumatic motor/nominal speed with oiled air
Nominal speed with unoiled air
Air consumption
Tab. 5
Cleaning unit
Actuation
Power consumption
Tab. 6
Inputs for activating the solenoid valves
1 output of inductive proximity switch (normally open switch) (pnp)
Operating voltage [U
Switching frequency [f]
Hysteresis [H]
Short-circuit and reverse polarity protection
Voltage drop [U
Operating current [I
Residual current [I
Idle current [I
]
0
Tab. 7
Power supply and output for proximity switch
BAL.0109 • 2020-12-15
]
B
]
d
]
L
]
r
3 Product description
+5 °C to +50 °C
Up to 90% at 20 °C
+5 °C to +50 °C
−10 °C to +55 °C
Up to 90% at 20 °C
Approx. 30 kg
365 × 290 × 1100
IP 21
1
G1/4"
Outer Ø 10 mm
6 bar
6–8 bar
Min. class 4
Approx. 650 rpm
Approx. 550 rpm
Approx. 380 L/min
3 inputs of the 5/2 directional valves
24 V DC ±10%
< 4.5 W
10–30 V
0–1500 Hz
Typ 5%
≤ 3 V
0–200 mA
0–0.5 mA typ 0.1 µA at 25 °C
≤ 20 mA